Difference between revisions of "Stacking Dell 10/40GbE MXL switches"

From Notes_Wiki
(Created page with "<yambe:breadcrumb>Switch_configuration_notes|Switch configuration</yambe:breadcrumb> =Stacking Dell 10/40GbE MXL Switches= Dell MXL 10/40GbE switches have Fiber Channel over...")
 
m
 
Line 1: Line 1:
<yambe:breadcrumb>Switch_configuration_notes|Switch configuration</yambe:breadcrumb>
[[Main Page|Home]] > [[Switch configuration notes]] > [[Stacking Dell 10/40GbE MXL switches]]
=Stacking Dell 10/40GbE MXL Switches=


Dell MXL 10/40GbE switches have Fiber Channel over Ethernet (FCoE) and Converged Network Adapter (CNA) support.  Hence, both Ethernet traffic and storage traffic can travel on the same port after bandwidth segregation.
Dell MXL 10/40GbE switches have Fiber Channel over Ethernet (FCoE) and Converged Network Adapter (CNA) support.  Hence, both Ethernet traffic and storage traffic can travel on the same port after bandwidth segregation.
Line 33: Line 32:




<yambe:breadcrumb>Switch_configuration_notes|Switch configuration</yambe:breadcrumb>
[[Main Page|Home]] > [[Switch configuration notes]] > [[Stacking Dell 10/40GbE MXL switches]]

Latest revision as of 05:15, 19 April 2022

Home > Switch configuration notes > Stacking Dell 10/40GbE MXL switches

Dell MXL 10/40GbE switches have Fiber Channel over Ethernet (FCoE) and Converged Network Adapter (CNA) support. Hence, both Ethernet traffic and storage traffic can travel on the same port after bandwidth segregation.

To stack two Dell MXL 10/40GbE switches we can use the following steps. Before using these steps the fiber storage modules (FC modules) should be removed as they dont allow stacking. It was observed that after creating the stack, if we reinsert FC storage modules the stack is not affected.

The better way might be to setup Virtual Link Trunking (VLT) so that during upgrades only one of the two switches needs to be rebooted. VLT insures that control plane of both VLT Peers is independent.

In any case if stacking is desired use following steps:

  1. Remove FC modules if any
  2. Run show system brief and verify that there is no stacking at present
  3. In config t
    stack-unit provision
    no stack-unit 0 port 33 portmode quad
    no stack-unit 0 port 37 portmode quad
    stack-unit 0 stack-group 0
    stack-unit 0 stack-group 1
    exit #from config t
    write memory
    reload
  4. After this fiber modules can be added again