Difference between revisions of "FCoE configuration on CNA"

From Notes_Wiki
(Created page with "<yambe:breadcrumb>Hardware_troubleshooting|Hardware troubleshooting</yambe:breadcrumb> =FCoE configuration on CNA= Often modern servers especially blades come with Converged...")
 
m
 
Line 1: Line 1:
<yambe:breadcrumb>Hardware_troubleshooting|Hardware troubleshooting</yambe:breadcrumb>
[[Main Page | Home]] > [[Hardware troubleshooting]] > [[FCoE configuration on CNA]]
=FCoE configuration on CNA=


Often modern servers especially blades come with Converged Network Adapters (CNA) which are capable of carrying both storage (FCoE) and network traffic.  To enable FCoE or converged mode on this adpaters in BIOS we need to use following settings:
Often modern servers especially blades come with Converged Network Adapters (CNA) which are capable of carrying both storage (FCoE) and network traffic.  To enable FCoE or converged mode on this adpaters in BIOS we need to use following settings:
Line 16: Line 15:
Refer:
Refer:
* http://mbhtech.blogspot.in/2013/08/configuring-fcoe-on-ibm-flex-nodes-and.html
* http://mbhtech.blogspot.in/2013/08/configuring-fcoe-on-ibm-flex-nodes-and.html
[[Main Page | Home]] > [[Hardware troubleshooting]] > [[FCoE configuration on CNA]]

Latest revision as of 07:15, 18 April 2022

Home > Hardware troubleshooting > FCoE configuration on CNA

Often modern servers especially blades come with Converged Network Adapters (CNA) which are capable of carrying both storage (FCoE) and network traffic. To enable FCoE or converged mode on this adpaters in BIOS we need to use following settings:

For Emulex CNA

Advanced Mode
Enable
Personality
FCoE
Multichannel Mode
IBM Unified Fabric Protocol Mode


For QLogic CNA

Virtualization Mode
NPAR (vNIC)


Refer: