Sonicwall analyzer setup
From Notes_Wiki
<yambe:breadcrumb>Sonicwall_firewall|Sonicwall firewall</yambe:breadcrumb>
Sonicwall analyzer setup
- Login to your mysonicwall.com account
- Navigate to Downloads > Free Downloads section.
- Select Software Type: "GMS/Analyzer - Windows" from drop-down list.
- Download latest analyzer for Windows
- Install analyzer using downloaded setup file. During installation give static IP of the analyzer machine and not the Sonicwall firewall.
- Reboot the system after sonicwall analyzer is installed
- Open http://127.0.0.1/ in browser
- Login with admin:password
- Set new admin password
- In Status click on "Register" link
- In Licenses
- login with sonicwall.com username and password
- Use serial number "ANALYZER" and give any friendly name. Leave authentication code empty, if not filled already
- Note the serial number displayed and save it before clicking continue
- Go to Deployment -> Roles. Fill in desired DB username and password. Click Update.
- To add sonicwall appliance to analyzer:
- Open URL http://localhost/sgms/auth
- Go to firewall tab
- Right click on "Global view" in left pane and choose "Add Unit"
- Give sonicwall appliance IP address, admin username and password
- Click ok
- Configure firewall to work with analyzer
- Login into firewall GUI
- Go to Log -> Syslog
- Add new syslog server. Give sonicwall analyzer IP and leave port 514
- Go to Log -> Analyzer
- Select "Enable Analyzer Settings"
- Click "Accept"
- Test by going to http://localhost/ in analyzer machine after waiting for 10-15 minutes.
Refer: